Product
AUTOMATIC SHUT OFF VALVE
S0167
Brass Gas Self Cut-off Valve with Test Point, F x M
Specification
Technical Data
■ Work Pressure: 2Kpa
■ Medium: Manufactured Gas, Natural Gas, and Liquefied Petroleum Gas
■ Over-Pressure Auto Shut-down: 8Kpa±2Kpa
■ Low-Pressure Auto Shut-down: Manufactured gas: 0.6Kpa±0.2Kpa
Natural gas: 0.8Kpa±0.2Kpa
Liquefied petroleum gas: 1.2Kpa±0.2Kpa
■ Closing Time: ≤3s
■ Flow: Rated Flow: 0.9m3/h;2.0m3/h
Cut Flow: 3.0m3/h
■ Suitable Gas Appliance: Water heater/wall mounted stove with power of 24KW and below
| Size | A | B | C | D | E x Eo | F x Fo | L |
| 15 | 28 | 36 | 42 | Φ8 | G1/2 x G1/2 | 13.5 x 13 | 153 |
| 15 | 28 | 36 | 42 | Φ10 | G1/2 x G1/2 | 13.5 x 13 | 155 |